ELEK Software Cable High Voltage

Overview

ELEK Software Cable High Voltage v7.0 – Professional Software for Power Cable Ampacity and Thermal Analysis from LV to HV/HVDC

 

ELEK Cable High Voltage is a specialized engineering program for calculating the permissible current load and heating of power cables, primarily medium- and high-voltage cables. It is used for designing cable lines from LV to HV/HVAC/HVDC.

The program’s main objective is to answer a fundamental engineering question: what current can a specific cable carry, either temporarily or continuously, under specific installation conditions, without the core temperature exceeding the permissible limit?

To answer this, the software performs detailed thermal analysis of the cable and its environment, considering all relevant factors including cable construction, installation geometry, soil properties, and environmental conditions.

Version 7.0 represents the latest release of this mature platform, building on decades of development by ELEK Software (formerly ELEK Cable High Voltage Software). The software is widely used by utilities, cable manufacturers, and engineering consultancies worldwide.

Screenshots
Key features
✓
Cable ConfigurationVoltage Levels: 110 kV, 132 kV, 220 kV, 330 kV and other HV/EHV levelsCore Cross-Section: User-defined cross-sectional areaCore Material: Copper (Cu) or Aluminum (Al)Insulation Type: XLPE, oil-filled, gas-filled, and other insulation systemsScreen and Sheath Design: Configuration of metallic screens and protective sheaths
✓
Installation EnvironmentAmbient Temperature: Ground or air temperature at installationSoil Thermal Resistivity: Thermal resistance of the surrounding soilBurial Depth: Depth of foundation or burialCable Spacing: Distance between adjacent cablesPhase Arrangement: Configuration of phases (trefoil, flat, etc.)Screen Grounding Method: Single-point, both-ends, or cross-bonded groundingNumber of Circuits: Single or multiple cable circuitsPipes and Channels: Presence of pipes, ducts, or channelsThermal Backfill: Use of special thermal backfill materials
✓
Analysis TypesContinuous Ampacity: Steady-state current ratingEmergency/Temporary Loading: Short-term overload capacityCyclic Loading: Daily or weekly load cyclesShort-Circuit Withstand: Thermal capacity under fault conditions
System requirements
Quick facts
VendorELEK
Latest version7.0
Interested in this software?

Send us your requirements and we’ll get back with availability, licensing.

0
Would love your thoughts, please comment.x
()
x